ISSN

2277 - 3282

e ISSN

2277 - 3290

Publisher

Journal of Science

FUNCTIONAL OUTCOME OF INTERNAL AND EXTERNAL FIXATION OF LOWER END RADIUS FRACTURES
Author / Afflication
Anil Kumar Gulia

Assistant Professor,Department of Orthopedics, BPS Govt Medical College for Women, Khanpur Kalan, Sonepat, Haryana, India.
Harnam S Madan

Assistant Professor, Department of Orthopedics, Shaheed Hasan Khan Mewati Government Medical College, Nalhar, Mewat, India
Prerna Malik

Assistant Professor, Department of Psychiatry, Pandit Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences, Rohtak, Haryana, India.
Harminder Singh

Postgraduate, Department of Physiology, Pandit Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences, Rohtak, Haryana, India.
Narender Rathee

Senior Resident,Department of Orthopedics, BPS Govt Medical College for Women, Khanpur Kalan, Sonepat, Haryana, India.
Dharvin Lamba

Postgraduate, Department of Physiology, Pandit Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences, Rohtak, Haryana, India.
Keywords
Fracture lower end radius ,External fixators ,Locking compression plate ,
Abstract

Fractures of lower end radius are most common fractures of the upper extremity, encountered in practice and constitute 17 % of all fractures. The present study was conducted with the aim of fixation of these fractures by external fixators and volar locking compression plating (LCP) and to optimize the treatment of different fractures. 128 adult patients with fracture of lower end radius were included in a randomized prospective study. 18 patients were lost in follow-up and were excluded from study. External fixators and locking compression plates (LCP) were applied .Results were calculated according to Gartland and Werley criteria, 110 cases were included in randomized prospective study, 85.45% (n= 94) were males and 14.54 % (n=16) were females. 52.7% fractures were of left and 47.3% were of right side. RTA was commonest (61.81%) injury mode. Largest number of cases was of Frykman’s Type III (30). 84 cases were fixed by LCP and 26 by external fixators. According to Gartland and Werley criteria results were excellent in 7.27% (n=8), Good in 78.18% (n=86), Fair in 12.72 %(n=14) and Poor in 1.81%(n=2). Stabilizing the fracture fragments with volar locking compression plate and external fixators in the management of the fractures of distal radius is an effective method.

Volume / Issue / Year

5 , 12 , 2015

Starting Page No / Endling Page No

1227 - 1232